COMMON MODE CHOKE COILS  [Leaded Common Mode Choke Coils for AC Lines]

Specifications

Status Discontinued
Common Mode Inductance 6800 uH min
Case Size (mm) 17.0x22.0
DC Resistance (max) 0.6 Ω
Rated Current (max) 0.8 A
Rated Voltage (max) AC250 V
Operating Temp. Range -25 to +105 ℃
(Including-self-generated heat)
Insulation Resistance (min) 100 MΩ
Dimension A Max 17.0 mm
Dimension B Max 22.0 mm
Dimension C Max 23.0 mm
RoHS Compliance (10 subst.) Yes
IEC62474 (Ver. D28.00) Compliance No(*)
Soldering Wave
Standard Quantity Bulk 500pcs

Appearance

Features

TLH10UA(B)TYPE : Ordinary configuration (Hybrid choke)

TLF9UA(H)K1 TYPE : Small-sized configuration

Main Applications

As a preventive measure against noise terminal voltage or power supply noise in
TV's SW power supplies, NC machines, computer systems, peripheral units,
measuring instruments, and controllers

Document

 

Simulation data

Links

 

RoHS and REACH Certificate of Compliance

Impedance-Frequency Characteristics
(*) Brominated flame retardants (other than PBDEs, PBBs, HBCDDs) are intentionally used. Bromine (in homogeneous materials) in this product exceeds 1000 ppm.